300
300
These sensors are designed for temperature measurement of nonaggressive liquid and gaseous media, that do not destruct thermowell material. It is also possible to measure solid body temperature. Sensors can be of explosion protection type 0ExiaIICT6 X. Further details see in "Alternative designs" below.
Movable fitting UNKJ 031 (see "UNKJ units and components" section) is recommended for sensor installation.
If required, thermocouples with 4-20 mА DC signal and/or digital signal via HART, PROFIBUS-PA, FOUNDATION Fieldbus protocol, can be equipped with remote measuring transmitters.
Connection diagram |
2-wire |
tolerance class В, С (see item 9 at page 6-5) |
|
3-wire |
tolerance class АА, А, В, С |
||
4-wire |
|||
Vibration resistance GOST R 52931 |
group V3 |
||
Seismic resistance MSK-64 |
grade 9 for unit installation up to 70 m above zero mark |
||
Climatic version |
UHL2Ambient temperature: |
-60..+120ºС for general purpose products |
|
-60..+85ºС for Ex version with analogous signal |
|||
Calibration |
- GOST 8. 461-2009 |
||
Response time |
Sensor response time depending on diameter, s |
||
d = 4 |
d = 5 |
d = 6 |
|
8 |
12 |
16 |
Group of operating |
Probability of |
Specified lifetime |
Mean |
Guarantee |
I |
0.95 for 40 000 hours |
5 years |
10 years |
5 years |
II |
0.95 for 16 000 hours |
2 years |
4 years (6 years)* |
2 years |
* - Increased mean lifetime with 0,6 failure-free operation possibility for the given period.
TC type |
Group of |
Tolerance |
Application |
Cal. int. |
Mean lifetime |
CRTD |
II |
А |
– 50…+120 |
2 years |
4 years |
B, C |
– 50…+150 |
||||
PRTD |
I |
A, B, С |
– 50…+150 |
5 years |
10 years |
II |
АА |
– 50…+150 |
2 years |
4 years |
PRTD |
|
Exi |
300 |
— |
0 |
60 |
— |
Pt100 |
— |
В |
3 |
— |
S10 |
— |
8 |
— |
L |
/ |
l |
|
|
1 |
|
2 |
3 |
|
4 |
5 |
|
6 |
|
7 |
8 |
|
9 |
|
10 |
|
11 |
|
12 |
|
13 |
NN |
Name |
Code |
Description |
||
1 |
Sensor type |
CRTD |
Copper resistance temperature detector |
||
PRTD |
Platinum resistance temperature detector |
||||
2 |
Explosion protection |
Not filled |
general purpose electrical equipment |
||
Exi |
0ExiaIICT6 X, intrinsically safe circuit |
||||
3 |
Modification |
300 |
see draft |
||
4 |
Terminal head |
0 |
Free electrode ends 50mm |
IP65 |
0ExiaIICT6Х or general purpose |
2 |
miniature plug |
IP40 |
general purpose |
||
4 |
standard plug |
IP40 |
general purpose |
||
5 |
Sensor terminal |
50 |
Stranded conductor, silicon / shield / silicon insulation - shield is insulated from sensor body and does not have a terminal |
||
60 |
Stranded conductor, PTFE / shield / PTFE insulation - shield is insulated from sensor body and does not have a terminal |
||||
6 |
Type of TC |
50М, 100М, 50P, 100P, Pt100, Pt500 |
NSC according to GOST 6651-2009 |
||
7 |
Tolerance class |
АА, А, В, С |
Tolerance class according to GOST 6651-2009 |
||
8 |
Connection diagram |
3, 4 |
3- and 4-wire connection diagram for class АА, А |
||
2, 3, 4 |
2-, 3-, 4-wire connection diagram for class В, С |
||||
9 |
Sheath material |
S10 |
steel 12Cr18Ni10T |
||
10 |
Outer diameter, mm |
4 |
for 60 modification wire |
||
5 or 6 |
for 50 modification wire |
||||
11 |
Probe length, L, mm |
60÷160 |
|
||
12 |
Extension wire length ℓ |
100÷30,000 |
specify dimensions in mm 500, 1000, 2000 3150 and more |
||
13 |
Additional |
Not filled |
Should be filled if required |
PRTD 300-060-Pt100-B3-S10-4-100/5000 |
|||
Product type |
PRTD |
Platinum resistance temperature detector |
|
Explosion protection |
― |
general purpose |
|
Modification |
300 |
|
|
Terminal head |
0 |
Free electrode ends |
|
Wire code |
60 |
PTFE sheath, IP65 |
|
Type of TC |
Pt100 |
|
|
tolerance class and connection diagram |
В3 |
Class B, diagram 3-wire |
|
Output signal (accuracy class) |
|
analogous according to NSC |
|
Sheath material |
S10 |
steel 12Cr18Ni10T |
|
Working end diameter |
4 |
mm |
|
Probe length L |
100 |
mm |
|
Wire length ℓ |
5000 |
mm |