Compensation and thermocouple wires

Compensation and thermocouple wires

PC TESEY offers foreign-made stranded thermocouple extension (compensation) wires.  Main wire types are given in the table.
Standard bundle length is 250 m. Wires can be also supplied on reels, up to 1000 m long.
Accuracy class according to GOST 60584-3: 1 or 2.

Designation
PC "Tesey"

Code according to
IEC 60584-3

Connected thermocouple
type (NSC)

Thermocouple wire
section,
mm2

Thermocouple wire
insulation
material

Shield
existence

Outer
sheath
material

Sheath heat
resistance,  °С

Colour code
according to IEC 60584-3

Thermocouple wire
insulation

Outer
sheath

«+»

«–»

TP Jх2150VVТ

J

1.5

PVC

PVC

105

black

white

black

TP Nх2100VVТ

Nx

N

1.0

pink

white

pink

TP Nх2150VVТ

Nx

N

1.5

pink

white

pink

TP Nх2150VEVТ

Nx

N

1.5

shield

pink

white

pink

TP Scb2150VVТ

Scb

TT

1.5

orange

white

orange

TP Scb2150FF

Scb

TT

1.5

PTFE

PTFE

210
(240)

orange

white

orange

TP Scb2150FEF

Scb

TT

1.5

shield

orange

white

orange

TP Кса2100VVТ

Kca

K

1.0

PVC

PVC

105

green

white

green

TP Кса2100VEVT

Kca

K

1.0

shield

green

white

green

TP Кса2150VVТ

Kca

K

1.5

green

white

green

TP Кса2150VEVT

Kca

K

1.5

shield

green

white

green

TP Кса2100FEF

Kca

K

1.0

PTFE

shield

PTFE

210 (240)

green

white

green

TP Кса2150FEF

Kca

K

1.5

shield

green

white

green

TP Кса2100FF

Kca

K

1.0

green

white

green

TP Кса2150FF

Kca

K

1.5

green

white

green

TP Кса2100SES

Kca

K

1.0

silicon rubber

shield

silicon rubber

200

green

white

green

TP Кса2150SES

Kca

K

1.5

shield

green

white

green

TP Кса2100SS

Kca

K

1.0

green

white

green

TP Кса2150SS

Kca

K

1.5

green

white

green

Solid thermocouple wire with mullite-silica, ceramic and silica fibre insulation are designed for use in high temperature conditions. These wires can be used for production of thermocouples (modification CTx 02.21) used as "charging" or "control" thermocouples in thermal processing equipment, homogenizing, annealing, ageing and tempering furnaces.
"Charging" ("embedded") thermocouples are used for temperature measurement of details, prototypes, blanks and feedstock. Charging thermocouple is installed inside material charge or in touch with it.
"Control" thermocouple is used for heating uniformity control or thermal field uniformity control during certification of furnace or other equipment.
Accuracy class according to IEC 60584-2:  1.


Designation
PC "Tesey"

Appearance

Type of TC

Thermocouple wire
diameter

Insulation and outer
sheath material

Sheath heat
resistance,  °С

TC J2080(1)VH

J

0,8 mm

High-temperature 
glass fibre

650 (700*)

TC К2080(1)VH

K

TC К2080(1)CA

K

ceramic fibre

1200 (1370*)

TC К2080(1)QA

K

silica fibre

1000

* – if there is no friction or bending.