01.26

  • 010
  • 16
  • 21
  • 23
  • 25
  • 26
  • 28

01.26

Thermocouples are designed for temperature measurement of glass melt and other corrosive liquid media.
TCS, TCR (TCB) thermocouple is located in multichannel ceramic tube, which is inside aluminium-oxide ceramic thermowell. Thermowell is protected with metal tip  LTHERMOWELL long made of platinum-rhodium alloy. Tip is fixed to heat-resistant Fe-Cr-45%Ni pipe by means of coupling nut. L, LTHERMOWELL, L1, L2, L3 dimensions should be explicitly specified at the time of thermocouple order. Thermocouple design is patented.
Temperature in transition zone between platinum-rhodium tip and metal reinforcement should not exceed 1000°С under operating conditions. Recommended thermocouple immersion depth in glass melt should be 30¸50 mm less than LTHERMOWELL.

Technical characteristics

tolerance class:1 and 2    for  TCS and TCR;  2 and 3    for TCB
material of thermowell metal reinforcement:  Т45 – alloy Fe-Cr-45%Ni
material of thermowell working part
ТPR10 – alloy: 90% platinum, 10% rhodium; ТPR20 – alloy: 80% platinum, 20% rhodium
Note: To prevent inner ceramic thermowell destruction due to high temperature gradient when thermowell is immersed in working medium, thermocouple heating rate should not exceed 150°С/min.
Hot junction: one, two or three,   ungrounded from thermowell metal reinforcement
Thermocouple wire diameter


Designation

Positive wire diameter
(PR10, PR13, PR30),  mm

Negative wire diameter
(PlT, PR6),  mm

А

0.5

0.5

В

0.4

0.5

С

0.4

0.4

Thermal inertia index  does not exceed 50 seconds
nominal (rated) pressure: 0.1 MPa

Temperature range

Operating temperature range, *С 0 - 1300 for TCS and TCR; 600 - 1600 for TCB

Execution options

Insertion length L: 500, 630, 800, 1000, 1250, 1600, 2000 mm.


Thermocouple
type

Design
modification

Wire
diameter

Tolerance
class**

Hot junction
number and type

Thermo-
well
material

Diameter
D, mm

Insertion
length, L, mm

Working part
length,
LTHERMOWELL , mm

modification

typical
version*

min

max

TCS, TCR, TCB

01.26

020
022

А, В, С

1, 2 (TCS, TCR);
2, 3 (TCB)

U,
U2, U3

ТPR10,
ТPR20

9
13

500

2000

from 70
to 250 mm

* – see Appendix for version description.
** – typical version: TCS, TCR - 2 tolerance class; TCB - 3 tolerance class.

Examples of product designation

TCS, TCR (TCB) 01.26-ХХХ - (А, В, С)Х - Ux - ТХХХ - D - L / LTHERMOWELL,   L1 / L2 / L3
TCS 01.26-020 – А2 - U - ТPR20 - 9 - 1250 / 250, 25 –type S calibration thermocouple TCS, modification 01.26-020 with 0.5+/0.5– mm thermocouple wire diameter (А), tolerance class 2, one ungrounded junction (U), platinum (ТPR20) end 9 mm diameter, total insertion length (L) 1250 mm, platinum tip length (LTHERMOWELL) 250 mm, element length L1=25.
TCB 01.26-022 - А3 - U3 - ТPR10 - 13 - 1000 / 100, 25 / 50 / 75 –type B calibration thermocouple TCB, modification 01.26-022 with 0.5+/0.5– mm thermocouple wire diameter (А), tolerance class 3, three ungrounded junctions (U3), platinum (ТPR10) tip 13 mm diameter, total insertion length (L) 1000 mm, platinum tip length (LTHERMOWELL) 100 mm, element length 25, 50, 75 mm.