01.24 тип ТППТ, ТПРТ
01.24 тип ТППТ, ТПРТ
Thermocouples 01.23, 01.24 are designed for temperature measurement in high-temperature gaseous non-corrosive media, and also in corrosive media that do not damage thermowell material. These modifications are similar to 01.21 in design, but they have additional mounting elements: flange for 01.23 and threaded fitting for 01.24.
Thermocouple 01.24А are designed for hydrogen, carbonic oxide, water vapour, and higher hydrocarbon temperature measurement. Thermocouple 01.24 is leak-tight in application. Thermocouple design provides nitrogen boost into inner thermocouple cavity.
Ceramic thermowell is partially armoured with assembly steel tube. Heat-resistant steel AISI310 tube is used in the area adjacent to thermowell ceramic part, steel 12Cr18Ni10T tube is used in other parts.
Stop ring 36 mm diameter and movable fitting with М39х2 thread are used for thermocouple mounting at site.
nominal (rated) pressure: 0.4 MPa
Tolerance class:
- 1 - 2 for TCS and TCR
- 2 - 3 for TCS and TCR
Thermowell material:
- C795 – aluminium-oxide ceramics, Al2O3 content is not less than 95%;
- C799 – aluminium-oxide ceramics, Al2O3 content is not less than 99.5%;
- CК90 – silicon carbide (SiC content is 88¸92%).
- Note: to prevent ceramic thermowell destruction due to high temperature gradient when thermowell is immersed in working medium, thermocouple heating rate should not exceed 150°С/min.
Hot junction: one, ungrounded from thermowell metal armour
Thermocouple wire diameter:
Designation |
|
|
|
|
|
|
|
|
|
|
|
Thermal inertia index Not rated
TC type |
operating temperature range, °С |
material of thermowell working part |
TCS, TCR |
0 to 1300 |
C795, C799, CК90 |
TCB |
600 to 1400 |
C795 – aluminium-oxide ceramics |
600 to 1600 |
C799 – aluminium-oxide ceramics |
Insertion length L: 630, 800, 1000, 1250, 1600 mm.
Thermocouple type |
Design |
Wire |
Tolerance class** |
Hot junction |
Thermo- |
Diameter |
Insertion |
Ceramic |
||
modification |
typical |
min |
max |
|||||||
TCS, TCR, TCB |
01.21 |
-020 |
А, В, С |
1, 2 2, 3 (TCB) |
U, U2 |
C795, C799 |
12 |
500 |
2000 |
400 to 1250 |
C799 |
15 |
|||||||||
-022 |
C795, C799 |
20 |
||||||||
CК90, CК99 |
22 |
400 to 600 |
||||||||
01.24 |
|
C795, C799 |
20 |
630 |
320 |
|||||
|
900 |
400 |
||||||||
|
1000 |
400 |
||||||||
|
1250 |
630, 1000 |
||||||||
|
1600 |
1000 |
* – see Appendix for version description.
** – typical version: TCS, TCR - 2 tolerance class; TCB - 3 tolerance class.
TCB 01.2х-022 - (А, В, С)Х - U - CХХХ - D - L / -(flange parameters or fitting dimensions) TCB 01.24А-022 - В3 - U - C799 - 20 - 1000/400 – type B calibration thermocouple TCB, design modification 01.24А-022 with nitrogen blow unit, 0.4+/0.5– mm thermocouple wire diameter (В), tolerance class 3, one ungrounded junction (U), aluminium-oxide ceramic thermowell C799 diameter 20 mm, insertion length (L) 1000 mm, ceramic part length (C ) 400 mm. TCS 01.23-022 – А1 - U - C799 - 20 - 1000/700/160-150.110.4х18 – type S calibration thermocouple TCS, design modification 01.23-022 with mounting flange, 0.5+/0.5– mm thermocouple wire diameter (В), tolerance class 1, one ungrounded junction (U), aluminium-oxide ceramic thermowell C799 diameter 20 mm, insertion length (L) 1000 mm, ceramic part length (C ) 700 mm, extension neck length 160 mm. Flat flange, outer diameter 150mm, center-to-center distance 110 mm, 4 holes 18 mm diameter TCR 01.24-022 – В2Н30 – U - C799 - 20 - 1000/400-М33 – type R thermocouple TCR, design modification 01.24-022 with threaded fitting, thread М33х2, 0.4+/0.5– mm thermocouple wire diameter (В), tolerance class 2, with installed measuring transmitter 4-20мА+HART, one ungrounded junction (U), aluminium-oxide ceramic thermowell C799 diameter 20 mm, insertion length (L) 1000 mm, ceramic part length (C ) 400 mm.