Thermocouples are designed for temperature measurement in liquid and gaseous non-corrosive media, and also corrosive media that do not damage protective cover material.
Thermocouple TCS, TCR (TCB) 01.20 is equipped with double thermowell made of aluminium-oxide ceramics, which has partial outer reinforcement with steel tube 12Cr18Ni10T. Temperature in transition zone between ceramic and metal thermowell parts should not exceed 800C under operating conditions.
For fitting length 500 mm thermowell ceramic part  (C) should be 250 mm long, for other fitting length thermowell ceramic part length should be in the range of 400–1250 mm. Length K should be clearly specified in order.
Ceramic part length should be selected depending on operating conditions, and taking into account, that at horizontal thermocouple operating position ceramic thermowell can be bent under high temperature.
At customer's request the thermocouple can be equipped with single thermowell made of gas-tight aluminium-oxide ceramics.
TCS, TCR (TCB) 01.20 thermocouple design with double ceramic thermowell is registered by the State register of utility models of the Russian Federation, utility model certificate No. 11392 issued by the Russian Patent Agency (Rospatent).
Movable fitting UNKJ 031, UNKJ 041 or movable mounting flange UNKJ 030 are recommended for thermocouple installation at site (see section 11)/

For measuring circuit connection thermocouples can be equipped with thermocouple adapter ATPP

Technical characteristics

Tolerance class
1 - 2 for TCS and TCR
2 - 3 for TCS and TCR
material of thermowell metal reinforcement
S10 – steel 12Cr18Ni10Т
material of thermowell working part
C795    – aluminium-oxide ceramics, Al2O3 content is not less than 95%;
C799    – aluminium-oxide ceramics, Al2O3 content is not less than 99.5%;
Note:to prevent ceramic thermowell destruction due to high temperature gradient when thermowell is immersed in working medium, thermocouple heating rate should not exceed 150°С/min
Hot junction
one or two,   ungrounded from thermowell metal reinforcement
Thermocouple wire diameter

Designation

Positive wire diameter
(PR10, PR13, PR30),  mm

Negative wire diameter
(PlT, PR6),  mm

А

0.5

0.5

В

0.4

0.5

С

0.4

0.4

Response time does not exceed:
40 s   for single thermowell made of aluminium-oxide ceramics;
100 s   for double thermowell made of aluminium-oxide ceramics;
nominal (rated) pressure
0.4 MPa

Temperature range

0 - 1300 for TCS and TCR
600 - 1600 for TCB

Execution options

Insertion length L: 500, 630, 800, 1000, 1250, 1600, 2000 mm.


Type

Design
modification

Wire
diameter

Tolerance
class**

Hot junction
number and type

Thermowell
material

Diameter
D, mm

Insertion
length, L, mm

Ceramic
part
length,
C , mm

modification

typical
version*

min

max

TCS, TCR, TCB

01.20

-020

А, В, С

1, 2 (TCS, TCR);

2, 3 (TCB)

U, U2

C795, C799

12

500

2000

400 to 1250
(250 mm for L=500)

-022

C795, C799

20

* – see Appendix for version description.
** – typical version: TCS, TCR - 2 tolerance class; TCB - 3 tolerance class.

Examples of product designation

TCS, TCR (TCB) 01.20-ХХХ - (А, В, С)Х - U(2) - Cххх - D - L / C

TCB 01.20-022 - А3 - U2 - C795 - 20 - 800 / 600 –calibration thermocouple TCB, modification 01.20-022 with 0.5+/0.5– mm thermocouple wire diameter (А), tolerance class 3, two ungrounded junctions (U2), double thermowell made of aluminium-oxide ceramics (C795) diameter 20mm, total insertion length (L) 800 mm, thermowell ceramic part length (C) 600 mm.

TCS 01.20-020 - B2 - U - C795 - 12 - 500 / 250 – type S calibration thermocouple TCS 10, modification 01.20-020 with 0.4+/0.5– mm thermocouple wire diameter (B), tolerance class 2, one ungrounded junction (U), single thermowell made of aluminium-oxide ceramics (C795) diameter 12mm, total insertion length (L) 500 mm, thermowell ceramic part length (C) 250 mm.