01.01 type TCS, TCR, TCB

  • 006

01.01 type TCS, TCR, TCB

Thermocouples are designed for temperature measurement in gaseous chemically-non aggressive liquid.
01.01 thermocouple, type TCS, TCR (TCB) is uncased. Solid dual-channel straw  £ is used for insulation of 400 mm wires. if thermocouple is longer than 400 mm, solid straw should be completed with dual-channel beads (bead is 50 mm long) up to the required length.
Straw and beads are made from aluminium-oxide ceramics. At customer's request, dual-channel straw of required length can be used for insulation, straw material is aluminium-oxide ceramics (C799).

Technical characteristics
  • Tolerance class: 1 or 2 for TCS and TCR; 2 or 3 for TCB
  • Thermowell material:aluminium-oxide ceramic straw and beads
  • Hot junction:one
  • Response time does not exceed:1 s
  • Thermocouple wire diameter:

Designation

Positive wire diameter
(PR10, PR13, PR30),  mm

Negative wire diameter
(PlT, PR6),  mm

А

0.5

0.5

В

0.4

0.5

С

0.4

0.4

Temperature range

0 - 1300 for TCS and TCR

600 - 1600 for TCB

Execution options

Main thermocouple versions, modification 01.01

Insertion length L: 320, 400, 500, 630, 800, 1000, 1250, 1600, 2000, 2500, 3150, 3550, 4000, 5000, 5600, 6300, 7100, 8000, 9000, 10000 mm.



Type

Design
modification

Wire
diameter

Tolerance
class*

Hot
junction
number
and type

Thermowell
material

Thermowell
diameter,
d, mm

Insertion
length, L, mm

modification

typical
version

min

max

TCS, TCR

01.01

-000

А, В, С

1, 2

G

C799

3 – 4

250

10000

TCB

2, 3

* – typical version: TCS, TCR - 2 tolerance class; TCB - 3 tolerance class.

Examples of product designation

TCS (TCB) 01.01-000 - (А, В, С)Х - Н - C799 - d - L,   where d –  ceramic beads and straw diameter.

TCS 01.01-000 - В2 - Н - C799 - 4 - 500 –  type 10 (S) calibration thermocouple TCS, design version 01.01-000, 0.4+/0.5– mm thermocouple wire diameter (В), tolerance class 2, straw and beads  are made of aluminium-oxide ceramics C799diameter 4 mm, insertion length (L) 500 mm.
ATTENTION!
01.01 thermocouples are supplied disassembled: wire thermocouple as a ring, and ceramic beads separately. During thermocouple assembly it is necessary to wear rubber gloves wiped with spirits to prevent thermocouple wire fouling. Beads should be threaded without force, avoiding thermocouple wire bending and stretching (thinning).
As thermocouple components do not bear identification marks, and we can not control thermocouple assembly, PC TESEY has no warranty liability concerning this product type.