UNKJ 022
UNKJ 022
Thermowells UNKJ 021 and UNKJ 023 are designed for sensor protection from highly aggressive media that do not destroy PTFE under relatively low temperature. Threaded fitting material - steel 12Cr18Hi10Т, protective tube - PTFE F4 or F4D. Under serious external loads it is recommended to use thermowell UNKJ 023 with PTFE tube with inner steel pipe armouring. PTFE external sheath thickness is not less than 1 mm.
Thermowells UNKJ 022 are designed for temperature sensors protection under operation in high-temperature gaseous medium. Distinctive feature of this modification is¾a ceramic protection tube. Threaded fitting material – steel 12Cr18Ni10Т. Maximum temperature at fitting - 600°С. Protection tube material - aluminium-oxide ceramics or silicon carbide, see table No. 1, "UNKJ thermowells" section. Thermowell can be used as an additional protection for platinum thermocouple in single protection tube 8-10 mm diameter. Protect from impacts and harsh heating or cooling during installation and operation! When thermowell is immersed in working medium, its heating rate should not exceed 150°С/min.
Thermowell UNKJ 021 and UNKJ 023 design is covered by utility model patents No. 61029 and No. 75466, and thermowell UNKJ 022 design is covered by utility model patent No. 61030.
Modification |
Nominal |
Connection thread М |
D, mm |
max Ø sensor, mm |
Thermowell insertion length L, mm |
Thermowell immersion length U, mm |
|
from |
to |
||||||
UNKJ 021 |
2,0 (20) |
М20х1,5; G1/2; К1/2” |
16 |
6 |
80 |
320 |
U=L-24* |
М27х2; G3/4; К3/4” |
20 |
8 |
500 |
||||
М33х2; G1; К1” |
20, 25 |
||||||
UNKJ 023 |
2,0 (20) |
М20х1,5; G1/2; К1/2” |
15 |
6 |
80 |
320 |
|
М33х2; G1; К1” |
20 |
8 |
500 |
||||
UNKJ 022 |
1,0 (10) |
М20х1,5; G1/2; К1/2” |
15 |
8 |
250 |
1600 |
|
М27х2; G3/4; К3/4”; М33х2; G1; К1” |
20 |
12 |
1600 |
||||
М33х2; G1; К1” |
22 |
10 |
630 |
||||
28 |
12 |
450 |
1200 |
* - reference size; please specify immersion length while placing order.
Connecting thread |
Version A |
Version B |
Version C |
||||||||
with groove to GOST 10549 |
with tapered |
according to GOST 22526 |
according to OST 26.260.460 |
||||||||
Pic. 1 |
Pic. 2 |
Pic. 3 |
Pic. 4 |
Pic. 5 |
|||||||
M |
Dm, mm |
ℓP , mm |
Dm, mm |
ℓP , mm |
К |
ℓP min , mm |
Dm, mm |
ℓP , mm |
Dm, mm |
ℓP , mm |
|
М20х1,5 |
31 |
17 |
— |
½ |
21.0 |
25 |
14 |
31 |
17 |
|
|
G1/2 |
31 |
17 |
¾ |
21.5 |
26 |
14 |
31 |
17 |
|
||
G3/4 |
— |
38 |
22 |
1 |
26.5 |
32 |
16 |
36 |
22 |
|
|
М27х2 |
38 |
22 |
1½ |
27.5 |
32 |
16 |
36 |
22 |
|
||
G1 |
48 |
32 |
— |
39 |
18 |
43 |
32 |
|
|||
М33х2 |
48 |
32 |
39 |
18 |
43 |
32 |
|
UNKJ |
|
022 |
¾ |
27 |
. |
А |
. |
20 |
¾ |
G1/2 |
. |
G |
¾ |
F4 |
¾ |
20 |
¾ |
630 |
1 |
|
2 |
|
3 |
|
4 |
|
5 |
|
6 |
|
7 |
|
8 |
|
10 |
|
11 |
Field no. |
Structure |
Field code |
Designation |
|
1 |
Manufacturer's code |
UNKJ |
|
|
2 |
Thermowell modification number |
021.023 |
prefabricated PTFE thermowell |
|
022 |
prefabricated ceramic thermowell |
|||
3 |
Mounting thread M |
20 |
М20х1,5 |
|
27 |
М27х2 |
|||
33 |
М33х2 |
|||
G1/2; G3/4; G1 |
straight pipe thread GOST 6357 |
|||
K1/2; K3/4; K1 |
British taper thread GOST 6111 |
|||
4 |
Design depending on thermowell seal at site |
A |
A version (according to GOST 10549) |
|
B |
B version (according to GOST 22526) |
|||
C |
C version for weldolet installation according to OST 26.260.460-99 |
|||
5 |
Nominal pressure |
20 |
nominal (rated) pressure in kgf/cm2 for UNKJ 021, 023 |
|
10 |
nominal (rated) pressure in kgf/cm2 for UNKJ 022 |
|||
6 |
Sensor inner thread N |
|
М20х1,5 – not specified |
|
G1/2; |
straight pipe thread GOST 6357 |
|||
K1/2; |
British taper thread GOST 6111 |
|||
7 |
Design depending on sensor seal inside thermowell |
|
for movable fitting (field is not filled) |
|
G |
for fixed fitting |
|||
8 |
Immersion end material |
F |
PTFE F-4, F-4D |
UNKJ 021, 023 |
C799 |
highly aluminium-oxide ceramics C799 |
UNKJ 022 |
||
C101, C050, C110 |
nitride ceramics Syalon |
|||
10 |
Working end outer diameter, D |
16, 20, 25 |
dimensions in mm |
for UNKJ 021 |
14, 18, 20 |
dimensions in mm |
for UNKJ 023 |
||
15, 20, 22, 24, 28 |
dimensions in mm |
for UNKJ 022 |
||
11 |
Sensor |
L |
Distance from sealing face, mm It is recommended to be selected from standard range, GOST 6636-69 |
UNKJ 021-20.А.20-F-16-120 - thermowell, modification 021, mounting thread М20х1,5, sealing surface, version А (according to GOST 10549) Nominal pressure 2 MPa. Thread М20х1,5 for a sensor with movable fitting. Protection tube material PTFE Ф, working part diameter 16 mm, fitting length 120mm.
UNKJ 022-27.В.10-C799-20-630 - thermowell, modification 022 mounting thread М27х2, sealing surface version В (according to GOST 22526). Nominal pressure 1 MPa M20x1,5 thread for a sensor with movable fitting. Protection tube material - highly aluminium-oxide ceramics C799, working part diameter 20 mm, fitting length 630mm.