UNKJ 020
UNKJ 020
Thermowells are designed for temperature sensors protection from mechanical or chemical impact of working medium in pressurized vessels, pipelines and other units, in which additional sensor protection is required.
UNKJ 020, UNKJ 024, UNKJ 124 thermowells have solid sheath. UNKJ 019 has a seamless tube sheath.
Thermowell flanges are produced according to GOST 12815, ASME B16.5, DIN 1092-1, GOST R 54432, and in compliance with customer's requirements specification including design documentation development and approval. Sealing surface versions are given in the table No. 1 of "UNKJ thermowells" section.
Thermowell material: S10 – steel 12Cr18Ni10Т, S08 – 08Cr18Ni10Т or S13 – 10Cr17Ni13М2Т, complete list of available materials is given in the table No.1 of "UNKJ thermowells" section.
We offer companion connecting flanges UNKJ 037 (see "UNKJ units and components" section), and also gaskets and fastenings (see "Components, additional equipment" section) for thermowell connection to units, equipment, vessels and tanks.
Coupling design of UNKJ thermowell flange and Immersion part is covered by utility model patent No. 39225.
Modification |
Nominal |
Nominal diameter DN |
D, mm |
d, mm |
max Ø sensor*, mm |
Thermowell fitting length L, mm |
Insertion |
|
from |
to |
|||||||
UNKJ 020 |
0.1 to 40.0 (1 to 400) |
25 to 100 |
23 |
— |
10 |
120 |
1300 |
U=L-(10…16) |
0.1 to 40.0 (1 to 400) |
50 to 100 |
35 |
— |
10 |
||||
UNKJ 024 |
0.1 to 40.0 (1 to 400) |
25 to 100 |
16 |
— |
8 |
|||
18÷35 |
— |
10 |
||||||
UNKJ 124 |
0.1 to 40.0 (1 to 400) |
25 to 100 |
20 |
12.5 |
8 |
|||
22 |
17.5 |
10 |
* at the time of order please specify whether it is possible to produce thermowell for larger sensor diameter.
UNKJ |
|
019 |
- |
02 |
. |
50 |
. |
63 |
- |
G1/2 |
. |
G |
- |
S13 |
. |
S |
- |
20 |
- |
630 |
/ |
150 |
1 |
|
2 |
|
3 |
|
4 |
|
5 |
|
6 |
|
7 |
|
8 |
|
9 |
|
10 |
|
11 |
|
12 |
Field no. |
Structure |
Field code |
Designation |
|
1 |
Manufacturer's code |
UNKJ |
|
|
2 |
Modification |
019 |
Flanged welded seamless tube sheath with plug |
|
020 |
Flanged solid tapered sheath |
|||
024;124 |
Flanged thermowell with solid cylinder sheath of constant (024) or variable (124) diameter |
|||
3 |
Version of |
01, 02, 03, 04, 05, 07 |
according to GOST 12815 |
|
RF, LM, LF, LT, LG, RTJ |
according to ASME B16.5 |
|||
B, C, D, E, F, H (J) |
according to DIN 1092-1, GOST R 54432 |
|||
4 |
Nominal diameter DN |
20 to 100 |
dimension in mm from the range according to GOST 28338 |
|
up to 3’’ |
Size (inch) according to ASME |
|||
5 |
Flange durability |
1 to 250 |
nominal (rated) pressure in kgf/cm2 from the rage according to GOST 26349 |
|
150# to 2500# |
class according to ASME |
|||
6 |
Inner thread for |
|
М20х1,5 – not specified |
|
G1/2; G1 |
straight pipe thread |
|||
K1/2; K1 |
British taper thread, only for installation of sensors with fixed fitting. |
|||
7 |
Version according to |
|
for movable fitting (field is not filled) |
|
G |
for fixed fitting |
|||
8 |
Thermowell material*: |
S10 |
steel 12Cr18Ni10T |
|
S08 |
steel 08Cr18Ni10Т |
|||
S13 |
steel 10Cr17Ni3M2T |
|||
S316 |
AISI 361Ti |
Not applicable for UNKJ 019 |
||
М400 |
Monel 400 |
|||
I825, I800 |
Incoloy 825, Incoloy 800 |
|||
Т904, Т446 |
AISI 904L, AISI 446 |
|||
Т310, Т600, Т625 |
AISI 310S, Inconel 600, Inconel 625 |
|||
9 |
Presence/absence of |
|
without coating |
|
S |
wear-resistant and corrosion-resistant coating |
|||
10 |
Outer diameter |
14; 16; 20; 30; 32 |
Tube diameter (mm) for UNKJ 019 |
|
23; 35 |
Thermowell sheath base diameter D for UNKJ 020 |
|||
16; 18-35 |
Thermowell sheath diameter D for UNKJ 024 |
|||
20; 22 |
Thermowell sheath diameter D for UNKJ 124 |
|||
11 |
Fitting length L |
120÷1300 |
Distance from sealing face, mm It is recommended to be selected from standard range, GOST 6636-69 |
|
12 |
Coating length |
l |
field is not filled if thermowell without coating is used. |
* at the time of order please specify whether it is possible to produce thermowell from other materials given in table 1 , page 9-3.
UNKJ 019-02.50.63-G1/2.Н-S13.S-20-630/150 - thermowell, modification 019, flange version 2 (GOST 12815) DN-50 mm, PN-6.3 MPa. For G1/2 thread sensor with fixed fitting. Sheath and flange material - S13 (10Cr17Ni13М2Т), sheath with coating (S), working end diameter 20 mm, fitting length 630 mm, coating length 150 mm.