UNKJ 020

Thermowells are designed for temperature sensors protection from mechanical or chemical impact of working medium in pressurized vessels, pipelines and other units, in which additional sensor protection is required.
UNKJ 020, UNKJ 024, UNKJ 124 thermowells have solid sheath. UNKJ 019 has a seamless tube sheath.
Thermowell flanges are produced according to GOST 12815, ASME B16.5, DIN 1092-1, GOST R 54432, and in compliance with customer's requirements specification including design documentation development and approval. Sealing surface versions are given in the table No. 1 of "UNKJ thermowells" section.
Thermowell material: S10 – steel 12Cr18Ni10Т, S08 – 08Cr18Ni10Т or S13 – 10Cr17Ni13М2Т, complete list of available materials is given in the table No.1 of "UNKJ thermowells" section.
We offer companion connecting flanges UNKJ 037 (see "UNKJ units and components" section), and also gaskets and fastenings (see "Components, additional equipment" section) for thermowell connection to units, equipment, vessels and tanks.
Coupling design of UNKJ thermowell flange and Immersion part is covered by utility model patent No. 39225.

Technical characteristics
Temperature range

Modification

Nominal
nominal PN,
MPa (kgf/cm2)

Nominal diameter DN

D, mm

d, mm

max Ø                   sensor*, mm

Thermowell fitting length L, mm

Insertion
length
U, mm

from

to

UNKJ 020

0.1 to 40.0 (1 to 400)

25 to 100

23

10

120

1300

U=L-(10…16)

0.1 to 40.0 (1 to 400)

50 to 100

35

10

UNKJ 024

0.1 to 40.0 (1 to 400)

25 to 100

16

8

18÷35

10

UNKJ 124

0.1 to 40.0 (1 to 400)

25 to 100

20

12.5

8

22

17.5

10

* at the time of order please specify whether it is possible to produce thermowell for larger sensor diameter.

Execution options

UNKJ

 

019

-

02

.

50

.

63

-

G1/2

.

G

-

S13

.

S

-

20

-

630

/

150

1

 

2

 

3

 

4

 

5

 

6

 

7

 

8

 

9

 

10

 

11

 

12

 

Field no.

Structure

Field code

Designation

1

Manufacturer's code

UNKJ

 

2

Modification

019

Flanged welded seamless tube sheath with plug

020

Flanged solid tapered sheath

024;124

Flanged thermowell with solid cylinder sheath of constant (024) or variable (124) diameter

3

Version of
flange
sealing surface

01, 02, 03, 04, 05, 07

according to GOST 12815

RF, LM, LF, LT, LG, RTJ

according to ASME B16.5

B,  C,  D,  E,  F,  H (J)

according to DIN 1092-1, GOST R 54432

4

Nominal diameter DN

20 to 100

dimension in mm from the range according to GOST 28338

up to 3’’

Size (inch) according to ASME

5

Flange durability
group

1 to 250

nominal (rated) pressure in kgf/cm2 from the rage according to GOST 26349

150# to 2500#

class according to ASME

6

Inner thread for
sensor

 

М20х1,5 – not specified

G1/2;  G1

straight pipe thread

K1/2;  K1

British taper thread, only for installation of sensors with fixed fitting.

7

Version according to
sensor sealing

 

for movable fitting (field is not filled)

G

for fixed fitting

8

Thermowell material*:

S10

steel 12Cr18Ni10T

S08

steel 08Cr18Ni10Т

S13

steel 10Cr17Ni3M2T

S316

AISI 361Ti

Not applicable for UNKJ 019

М400

Monel 400

I825, I800

Incoloy 825, Incoloy 800

Т904, Т446

AISI 904L, AISI 446

Т310, Т600, Т625

AISI 310S, Inconel 600, Inconel 625

9

Presence/absence of
thermowell sheath coating

 

without coating

S

wear-resistant and corrosion-resistant coating

10

Outer diameter
of working end, D

14; 16; 20; 30; 32

Tube diameter (mm) for UNKJ 019

23; 35

Thermowell sheath base diameter D for UNKJ 020

16; 18-35

Thermowell sheath diameter D for UNKJ 024

20; 22

Thermowell sheath diameter D for UNKJ 124

11

Fitting length L

120÷1300

Distance from sealing face, mm It is recommended to be selected from standard range, GOST 6636-69

12

Coating length

l

field is not filled if thermowell without coating is used.

Examples of product designation

* at the time of order please specify whether it is possible to produce thermowell from other materials given in table 1 , page 9-3.
UNKJ 019-02.50.63-G1/2.Н-S13.S-20-630/150  - thermowell, modification 019, flange version 2 (GOST 12815) DN-50 mm, PN-6.3 MPa. For G1/2 thread sensor with fixed fitting. Sheath and flange material -  S13 (10Cr17Ni13М2Т), sheath with coating (S), working end diameter 20 mm, fitting length 630 mm, coating length 150 mm.