Band electric heating cables EHC-B
Band electric heating cables EHC-B
These electric heaters are designed for outer heating of pipelines, material cylinders of moulding machines, extruders, working surfaces of press dies and injection moulding machines.
Electric heater consists of a heating element and a case. Case is made of 12Cr18Ni10T steel.
Heating element is made from 2 or 3 mm diameter heating cable KNMCNH-N. Cable conductor - Cr20Ni80 alloy, cable sheath - stainless steel 12Cr18Ni10T.
For AC or DC main connection electric heaters are equipped on default with current-carrying wires 250 mm long, made of PRKA wire in high-temperature insulation (up to 180°С). Lead length can be increased.
On customer's request electric heater can be equipped with M5 threaded contact bar. At the time of order this request should be specified as version 2
Operating and outer surface temperature of electric heater does not exceed 600°С – in running condition under heat removal with natural air convection.
Operating voltage:220 V specific heat flow rate:3-5 W/cm2
minimum possible heated area value:
Electric power, N, W |
500 |
630 |
800 |
1000 |
1250 |
1500 |
2000 |
2500 |
3000 |
3500 |
4000 |
Minimum possible heated area value, S*, mm2 |
34000 |
25000 |
21500 |
31500 |
51000 |
43000 |
52000 |
57500 |
74500 |
120500 |
100500 |
* – heated surface area S = 3,14 x D x H.
Electric heating cables having power greater than 2 kW are equipped with two heating elements.
Electric heating cables with mounting diameter greater than 500 mm have two sections.
Table of band electric heating cable designs with power up to 2 kW.
EH modification |
Mounting width range H, mm |
Electric power, N, W |
||||||||||
D=80 |
D=90 |
D=100 |
D=125 |
D=160 |
D=175 |
D=200 |
D=250 |
D=320 |
D=400 |
D=500 |
||
EHC-B |
- |
120 |
120 |
90…120 |
70…120 |
- |
- |
- |
- |
- |
- |
500 |
120 |
100...120 |
90…120 |
70…120 |
60…120 |
- |
- |
- |
- |
- |
- |
630 |
|
90…120 |
80…120 |
70…120 |
60…120 |
50…120 |
- |
- |
- |
- |
- |
- |
800 |
|
120 |
- |
120 |
100…120 |
80…120 |
- |
- |
- |
- |
- |
- |
1000 |
|
- |
100…120 |
90…120 |
80…120 |
60…120 |
60…120 |
50…120 |
50…120 |
- |
- |
- |
1250 |
|
- |
- |
- |
120 |
80…120 |
80…120 |
70…120 |
50…120 |
- |
- |
- |
1500 |
|
- |
- |
- |
- |
120 |
- |
90…120 |
- |
60…120 |
50…120 |
50…120 |
2000 |
Table of band electric heating cable designs with power greater than 2 kW.
EH modification |
Mounting width range H, mm |
Electric power, N, W |
||||||||
D=160 |
D=200 |
D=250 |
D=320 |
D=400 |
D=500 |
D=630 |
D=800 |
D=1000 |
||
EHC-B |
120 |
100…120 |
80…120 |
70…120 |
70…120 |
70…120 |
- |
- |
- |
2500 |
- |
- |
120 |
70…120 |
70…120 |
70…120 |
50…120 |
50…120 |
50…120 |
3000 |
|
- |
- |
- |
80…120 |
70…120 |
70…120 |
50…120 |
50…120 |
50…120 |
3500 |
|
- |
- |
- |
70…120 |
70…120 |
70…120 |
50…120 |
50…120 |
50…120 |
4000 |
Limit allowable deviation of nominal power according to GOST 13268-88: –10% to +5%.
EHC-B ([2]) D ´ H. N. U (version 2)
EHC-B 160´90. 1500. 220 – band electric heating cable, cable diameter 160 mm, width 90 mm, power 1500 W, running voltage 220 V (wire output 250 mm long).