01.25
01.25
01.19 temperature sensors are designed for temperature measurement in melt aluminium and non-ferrous metals, and also in barium chloride bath.
For melt aluminium and non-ferrous metals temperature measurement it is recommended to use thermocouples with thermowell made of cast iron Ci or silicon nitride ceramic; for barium chloride temperature measurements - thermocouples with thermowell made of 12Cr18Ni10T steel.
Straight thermocouple can be dismantled, thermowell can be replaced in operation. Cable temperature-sensing element is partially armoured with steel tube. Temperature in connection point of thermowell and fitting should not exceed 800°С.
Thermocouple service life is not rated and is determined by thermowell destruction speed in medium being measured.
According to operating data from various plants, thermowell service life is:
- 8 to 12 months for thermowell made of silicon nitride ceramic and being used in melt aluminium;
- 10 to 30 days for thermowell made of cast iron and being used in melt aluminium;
- 10 to 30 days for thermowell made of 12Cr18Ni10T steel and being used in barium chloride bath.
Thermocouple immersion length should not exceed 80% thermowell length (thermowell).
01.25 temperature sensors are designed for temperature measurement in liquid and gaseous media, that are corrosive for thermowell material. These sensors can be dismantled, and consist of cable temperature-sensing element (can be supplied separately) and heat-resistant thermowell.
Assembly thermowell is equipped with solid tip with inner bore for temperature-sensing element. Tip is made of heat-resistant alloy or heat-resistant steel. 01.25 sensor service life depends on tip corrosion speed due to chemical and thermal effect of medium being measured. Reliability values stated below are given assuming that corrosion depth for the specified lifetime does not exceed 2mm.
Two 01.25 thermowell parts are welded together by argon-arc welding. Temperature at welding point during operation should not exceed 800°С.
Terminal heads can be equipped with transmitters with 4-20 mА DC output signal and/or digital signal via HART, PROFIBUS-PA, FOUNDATION Fieldbus protocol. It is recommended to use heads of 16, 23, 28 modifications for easy wire connection to transmitters. Terminal head can be equipped with standard or special-purpose cable gland. For further details see "Alternative designs & Ordering information" below.
Hot junction |
one, two |
Ungrounded |
||
Vibration resistance GOST R 52931 |
group N2 |
01.19 modification |
||
group V3 |
01.25 modification |
|||
Nominal (rated) |
0.1 MPa |
01.19 modification |
||
6.3 MPa |
01.25 modification |
|||
Seismic resistance MSK-64 |
grade 9 for unit installation up to 70 m above zero mark |
|||
Climatic category GOST 15150 |
UHL2Ambient temperature: |
-60..+120ºС for general purpose products |
||
-55..+85ºС for products with unified output signal |
||||
Calibration |
Only initial during production, are not subject to periodic calibration |
Group of operating conditions |
Probability of |
Specified lifetime |
Mean |
Guarantee |
I |
0.95 for 40 000 hours |
5 years |
10 years |
5 years |
II |
0.95 for 16 000 hours |
2 years |
4 years |
2 years |
III |
0.95 for 8 000 hours |
1 year |
2 years |
1 year |
IV |
Not rated |
Not rated |
Not rated |
Not rated |
Measurement accuracy of sensors with 4-20 mА DC signal and/or digital signal via HART protocol are given taking into account accuracies of thermocouple itself, transmitter and transmitter's cold junction compensation.
Output signal |
Symbol |
Measurement accuracy |
Output |
Symbol |
Measurement accuracy |
4-20mА |
c0Т40 |
±0,4% ∙tn* or ±1,5°С |
4-20mА+HART |
c1N25 |
±0,25%∙ tn or ±0,9°С; |
c1Т50 |
±0,5%∙ tn or ±2,0°С |
c0N40 |
±0,4%∙ tn or ±1,2°С; |
||
c2Т80 |
±0,8%∙ tn or ±2,5°С; |
c1N50 |
±0,5%∙ tn or ±1,7°С; |
||
|
|
c2N80 |
±0,8%∙ tn or ±2,5°С; |
* - tn sensor adjustment range should be multiplied by specified value in %. Select higher value.
CT type |
Modification |
Thermowell diameter |
Thermowell material |
Group of |
Application |
Calibration |
Mean lifetime |
CTK CTN |
01.19 |
40, 60 |
S10 |
IV |
-40…+1250 |
Not |
Not |
28 |
C101 |
||||||
40 |
GI |
||||||
01.25 |
14÷30 |
Т45 |
-40…+1250 |
||||
Т310 |
-40…+1150 |
||||||
CTN |
Т45,Т310 |
I |
-40…+800 |
5 years |
10 years |
||
II |
-40…+1100 |
2 years |
4 years |
||||
CTK |
Т18, Т00,Т310 |
I |
-40…+600 |
5 years |
10 years |
||
Т18, Т00 |
II |
-40…+900 |
2 years |
4 years |
|||
Т18, Т00 |
III |
-40…+1000 |
1 year |
2 years |
|||
Т310 |
-40…+1100 |
Response |
70 s |
S10, GI diameter 40mm |
01.19 modification |
90 s |
C101 diameter 28 |
01.19 modification |
|
50 s |
Т45, Т00, Т18, Т310 diameter 20mm |
01.25 modification |
CTK |
|
|
01.19 |
— |
0 |
20 |
— |
c1 |
|
— |
U |
|
— |
GI |
— |
40 |
— |
L |
/ |
lthermowell |
— |
lbend |
1 |
|
2 |
3 |
|
4 |
5 |
|
6 |
7 |
|
8 |
9 |
|
10 |
|
11 |
|
12 |
|
13 |
|
14 |
NN |
Name |
Code |
Description |
||||||||
1 |
Sensor type |
CTK, CTL, CTN |
Mineral insulated cable thermocouple with type according to IEC 60584 and ASTM E230 |
||||||||
2 |
Explosion protection |
Not filled |
general purpose electrical equipment |
||||||||
3 |
Modification |
01.19 |
thick-walled thermowell, straight, without fitting |
||||||||
01.19A |
thick-walled thermowell, angle, without fitting |
||||||||||
01.25 |
thick-walled thermowell, straight, with screw-in fitting |
||||||||||
4 |
Cable gland |
0 |
standard cable gland of terminal head |
||||||||
А-Z |
Special cable gland (see table 3 page 1-13) |
||||||||||
5 |
Sensor terminal |
15; 16;17; 18; 19 |
aluminium head |
IP66/IP68 |
1ExdIICT6 / 0ExiaIICT6 X |
||||||
20; 22 |
aluminium head |
IP65 |
general purpose |
||||||||
14; 21; 23; 24; 25; 26; 28; 29 |
aluminium head |
IP66 |
0ExiaIICT6Х or general purpose |
||||||||
27 |
stainless steel |
IP66 |
0ExiaIICT6Х or general purpose |
||||||||
6 |
Tolerance class |
c1; c2 |
For further details see table 5 page 2-9 |
||||||||
7 |
Output signal, transmitter accuracy symbol, see table 5, page 2-10 |
Not filled |
analogous signal according to NSC |
||||||||
Т40 |
4-20 mА |
for c0 |
|||||||||
Т50; Т70 |
for c1 |
||||||||||
Т80; Т100 |
for c2 |
||||||||||
H25 |
4-20 mА +HART |
Individual sensor calibration (c1) |
|||||||||
H40 |
for c0 |
||||||||||
H50 |
for c1 |
||||||||||
H80 |
for c2 |
||||||||||
8 |
Sensor hot junction design |
G |
grounded junction, |
general purpose |
|||||||
U |
ungrounded junction, |
1ExdIICT6 / 0ExiaIICT6 X / general purpose |
|||||||||
9 |
Number of wire couple |
Not filled |
1 wire couple |
||||||||
2 |
2 wire couples (2 junctions) |
||||||||||
10 |
Safety fitting |
S10 |
steel 12Cr18Ni10T |
D=40, 60 mm |
lthermowell≤2000 mm |
||||||
GI |
Grey Iron |
D=40 mm |
lthermowell≤2000 mm |
||||||||
C101 |
Silicon nitride ceramics |
D=28 |
lthermowell≤1365 mm |
||||||||
Т18 |
steel 10Cr23Ni18 |
10÷40 |
lthermowell≤1300 mm |
||||||||
Т45 |
alloy CrNi45U |
||||||||||
Т00 |
alloy 15Cr25Т |
||||||||||
11 |
Outer diameter, D |
14, 16, 20, 25 |
size (mm) on Customer's choice |
01.25 |
|||||||
40; 28 |
01.19 |
||||||||||
12 |
Probe length, L |
450÷3150 |
probe length L to the working end, mm |
||||||||
13 |
Size of lthermowell |
250÷2000 |
specify dimensions in mm |
01.19, 01.19U |
|||||||
Extension neck length |
80-500 |
specify dimensions in mm |
01.25 |
||||||||
14 |
Additional information |
Not filled |
|
01.19 |
|||||||
Size of lbend |
300÷2000 |
dimensions in mm |
for 01.19U |
||||||||
Fitting standard size |
Not filled |
without welded fitting |
for 01.25 |
||||||||
М33, М27, М20, C1, C3/4 |
М33х2, М27х2, C1”, C3/4” |
CTK Exi01.25-A23 - c1H50 - U - Т18 - 20 - 500/ 160-М33 – chromel-alumel temperature sensor, explosion protection 0ExiaIICT6Х , structural modification 01.25 with terminal head made of aluminium alloy (023), primary thermocouple tolerance class 1, 4-20mА DC output signal via HART protocol (H50), ungrounded junction (U), thermowell made of heat-resistant steel 10Cr23Ni18 (Т18), diameter 20 mm, 500 mm insertion length (solid end length), 200 mm length from fitting to terminal head, fitting thread М33х2.