01.15
01.15
01.11 temperature sensors are designed for temperature measurement in gaseous media, natural gas combusion products, and gas flows in main gas pipeline compressor stations at gas flow rate up to 70 m/s in front of protective shield of sensor working end. 01.11 sensors can not be dismantled. In 01.11 with terminal head in form of extension lead, temperature-sensing element is located outside of protective tube for the length of Ê. Thinned part diameter (d1) is equal to 5mm (7mm for CTL with two hot junctions). Fitting thread type should be specified in order.
01.14 temperature sensors are designed for temperature measurement in pulsating gas flow. 01.14 sensor can be dismantled for temperature-sensing element replacement. Fitting is welded to thermowell. Maximum allowable flow rate is calculated on the basis of density and measured fluid temperature. The flow rate should not exceed 170 m/s.
01.15 temperature sensors are designed for blast-furnace and inwall temperature measurement. The screw is intended for easy thermocouple dismantling.
01.12 and 01.13 temperature sensors are designed for gas flow temperature measurement. These sensors are noted for quicker thermal reaction as compared to 01.06, 01.08. Sensors can not be dismantled.
Limit gas flow rate of 01.12 and 01.13 sensors depends on thermowell material, probe length, mobile fluid immersion length, fluid temperature and density. Example of maximum speed for 01.13 modification with 10Cr17Ni13М2Т steel thermowell at fluid density 10 kg/cm2 and temperature 600°С is given in the table below on condition that sensor immersion length is equal to probe length.
Mounting part, L, mm |
Limit flow rate, m/s |
250 |
90 |
320 |
70 |
400 |
60 |
500 |
45 |
630 |
35 |
800 |
25 |
Flow rate at other operating conditions or sensor modification can be calculated on customer's request.
Sensors can be of explosion protection type 0ExiaIICT6 X or 1ExdIICT6 according to GOST 30852.10-2002. For further details see "Alternative designs & Ordering information" below. Terminal heads can be equipped with transmitters with 4-20 mА DC output signal and/or digital signal via HART, PROFIBUS-PA, FOUNDATION Fieldbus protocol. It is recommended to use heads of 16, 23, 28 modifications for easy wire connection to transmitters. Terminal head can be equipped with standard or special-purpose cable gland. For further details see "Alternative designs & Ordering information" below.
Hot junction |
one |
Ungrounded or Grounded |
|
two |
|||
Vibration resistance GOST R 52931 |
group V3 |
||
Seismic resistance MSK-64 |
grade 9 for unit installation up to 70 m above zero mark |
||
Climatic category GOST 15150 |
UHL2Ambient temperature: |
-60..+120ºС for general purpose products |
|
-60..+85 ºС for Ex version with analogous signal |
|||
-55..+85ºС for products with 4-20mА signal |
|||
Calibration |
- MI 3090-2007 – for sensor fitting length 20 - 250 mm, without measuring transmitters; |
Reliability measures
Group of operating conditions |
Probability of |
Specified lifetime |
Mean |
Guarantee |
II |
0.95 for 16 000 hours |
2 years |
4 years |
2 years |
III |
0.95 for 8 000 hours |
1 year |
2 years |
1 year |
IV |
Not rated |
Not rated |
Not rated |
Not rated |
Measurement accuracy of sensors with 4-20 mA DC signal and/or digital signal via HART protocol are given taking into account accuracies of thermocouple itself, transmitter and transmitter's cold junction.
Output signal |
Symbol |
Measurement accuracy |
Output |
Symbol |
Measurement accuracy |
4-20mА |
c0Т40 |
±0,4% ∙tn* or ±1,5°С |
4-20mА+HART |
c1N25 |
±0,25%∙ tn or ±0,9°С; |
c1Т50 |
±0,5%∙ tn or ±2,0°С |
c0N40 |
±0,4%∙ tn or ±1,2°С; |
||
c2Т80 |
±0,8%∙ tn or ±2,5°С; |
c1N50 |
±0,5%∙ tn or ±1,7°С; |
||
|
|
c2N80 |
±0,8%∙ tn or ±2,5°С; |
* - tn measuring transmitter adjustment range should be multiplied by specified value in %. Select higher value.
CT type |
Modification |
Thermowell diameter, mm |
Thermowell material |
Group of |
Application |
Calibration |
Mean lifetime |
CTL |
01.11, |
10 |
S10 |
II |
-40…+600 |
2 years |
4 years |
III |
-200…+800 |
1 year |
2 years |
||||
CTK |
10 |
T18 |
II |
-40…+900 |
2 years |
4 years |
|
CTN |
II |
-40…+1000 |
2 years |
4 years |
|||
CTN |
01.14 |
22 |
Т45, |
II |
-200…+800 |
2 years |
4 years |
III |
-200…+1100 |
1 year |
2 years |
||||
CTK |
II |
-200…+600 |
2 years |
4 years |
|||
III |
-200…+900 |
1 year |
2 years |
||||
IV |
-200…+1150 |
Not rated |
|||||
CTK |
01.12, 01.13, 01.15 |
20 |
T310, |
II |
-200…+900 |
2 years |
4 years |
III |
-200…+1100 |
1 year |
2 years |
||||
IV |
-200…+1150 |
Not rated |
|||||
CTN |
20 |
Т45 |
II |
-200…+1000 |
2 years |
4 years |
|
IV |
- 200…+ 1250 |
Not rated |
Response time τ 0,63:
Hot junction |
Sensor response time depending on diameter, s |
|||
modification |
modification |
01.15 modification |
||
d=10/5; 20/5 |
d=10/7; 20/7 |
d = 22 |
d = 20 |
|
Insulated from sheath |
5 |
7 |
8 |
40 |
Uninsulated from sheath |
3 |
5 |
7 |
- |
CTK |
|
|
01.14 |
— |
0 |
21 |
— |
c1 |
|
— |
U |
2 |
— |
Т45 |
— |
20 |
/ |
7 |
— |
L |
/ |
l |
— |
M33 |
1 |
|
2 |
3 |
|
4 |
5 |
|
6 |
7 |
|
8 |
9 |
|
10 |
|
11 |
|
12 |
|
13 |
|
14 |
|
15 |
NN |
Name |
Code |
Description |
||||
1 |
Sensor type |
CTK, CTL, CTN |
Mineral insulated cable thermocouple with type according to IEC 60584 and ASTM E230 |
||||
2 |
Explosion protection |
Not filled |
general purpose electrical equipment |
||||
Exi |
0ExiaIICT6 X, intrinsically safe circuit |
||||||
Exd |
1ExdIICT6, explosion-proof enclosure |
||||||
3 |
Modification |
01.11 |
with protective tube and thinning |
||||
01.12 |
without mounting elements, fast-response |
||||||
01.13 |
with welded fitting, fast-response |
||||||
01.14 |
solid tapered tube with thinning |
||||||
01.15 |
thermowell made of constant-diameter pipe |
||||||
4 |
Cable gland |
0 |
standard cable gland |
Not permitted for 1ExdIICT6 |
|||
А-Z |
Special cable gland (see table 3 page 1-13) |
||||||
5 |
Sensor terminal |
15; 16 |
aluminium head |
IP66/IP68 |
1ExdIICT6 / 0ExiaIICT6 X |
||
20; 22 |
aluminium head |
IP65 |
general purpose |
||||
21; 23; 24; 25; 26; 28; 29 |
aluminium head |
IP66 |
0ExiaIICT6 Х or general purpose |
||||
50 |
Stranded conductor, silicon / shield / silicon insulation - shield is insulated from sensor body and does not have a terminal |
||||||
60 |
Stranded conductor, PTFE / shield / PTFE insulation - shield is insulated from sensor body and does not have a terminal |
||||||
6 |
Tolerance class |
c0; c1; c2 |
For further details see table 5 page 2-9 |
||||
7 |
Output signal, transmitter accuracy symbol, see table 5, page 2-10 |
Not filled |
analogous signal (mV) according to NSC |
||||
Т40 |
4-20 mА |
for c0 |
|||||
Т50; Т70 |
for c1 |
||||||
Т80; Т100 |
for c2 |
||||||
H25 |
4-20 mА +HART |
Individual sensor calibration (c1) |
|||||
H40 |
for c0 |
||||||
H50 |
for c1 |
||||||
H80 |
for c2 |
||||||
8 |
Sensor hot junction design |
G |
grounded junction, general purpose |
||||
U |
ungrounded junction |
1ExdIICT6 / 0ExiaIICT6 X / general purpose |
|||||
9 |
Number of wire couples |
Not filled |
1 wire couple |
||||
2 |
2 wire couples (2 junctions) |
||||||
10 |
Protective sheath material |
S10 |
steel 12Cr18Ni10T |
||||
Т310 |
AISI 310 |
||||||
Т45 |
alloy CrNi45U |
||||||
11 |
Basic outer diameter |
10; 20; 22 |
size (mm) on Customer's choice |
||||
12 |
Outer thinning diameter |
5, 7 |
size (mm) on Customer's choice |
Except for 01.15 |
|||
13 |
Probe length |
50÷2500 |
probe length L to the working end, mm |
||||
14 |
Extension neck length l |
Not filled |
if equal to 120 mm or there are no mounting elements |
||||
30÷500 |
specify dimension in mm, oif 120 mm doesn't fit |
||||||
15 |
Fitting standard size |
Specify thread size |
C1/2, М27х2, М33х2 |
Except for 01.12 |
|
Product type |
CT |
cable thermocouple |
Type |
K |
chromel-alumel |
|
Explosion protection |
― |
|
|
Modification |
01.15 |
|
|
Cable gland |
0 |
standard |
|
Wring (terminal head code) |
20 |
with latch, IP65 |
|
Tolerance class |
c1 |
first class |
|
Output signal |
|
analogous |
|
Junction type, number of pairs |
U2 |
iwo, ungrounded |
|
Cable sheath material |
Т45 |
alloy CrNi45T |
|
Working end diameter |
20 |
mm |
|
Probe length |
800 |
mm |
|
Extension neck length |
― |
120 mm |
|
Fitting standard size |
M33 |
М33х2 |