01.15

01.11 temperature sensors are designed for temperature measurement in gaseous media, natural gas combusion products, and gas flows in main gas pipeline compressor stations at gas flow rate up to 70 m/s in front of protective shield of sensor working end. 01.11 sensors can not be dismantled. In 01.11 with terminal head in form of extension lead, temperature-sensing element is located outside of protective tube  for the length of Ê. Thinned part diameter (d1) is equal to 5mm (7mm for CTL with two hot junctions). Fitting thread type should be specified in order.
01.14 temperature sensors are designed for temperature measurement in pulsating gas flow. 01.14 sensor can be dismantled for temperature-sensing element replacement. Fitting is welded to thermowell. Maximum allowable flow rate is calculated on the basis of density and measured fluid temperature. The flow rate should not exceed 170 m/s.
01.15 temperature sensors are designed for blast-furnace and inwall temperature measurement. The screw is intended for easy thermocouple dismantling.
01.12 and 01.13 temperature sensors are designed for gas flow temperature measurement. These sensors are noted for quicker thermal reaction as compared to 01.06, 01.08. Sensors can not be dismantled.
Limit gas flow rate of 01.12 and 01.13 sensors depends on thermowell material, probe length, mobile fluid immersion length, fluid temperature and density. Example of maximum speed for 01.13 modification with 10Cr17Ni13М2Т steel thermowell at fluid density 10 kg/cm2 and temperature 600°С is given in the table below on condition that sensor immersion length is equal to probe length.


Mounting part, L, mm

Limit flow rate, m/s

250

90

320

70

400

60

500

45

630

35

800

25

Flow rate at other operating conditions or sensor modification can be calculated on customer's request.
Sensors can be of explosion protection type 0ExiaIICT6 X or 1ExdIICT6 according to GOST 30852.10-2002. For further details see "Alternative designs & Ordering information" below. Terminal heads can be equipped with transmitters with 4-20 mА DC output signal and/or digital signal via HART, PROFIBUS-PA, FOUNDATION Fieldbus protocol. It is recommended to use heads of 16, 23, 28 modifications for easy wire connection to transmitters. Terminal head can be equipped with standard or special-purpose cable gland. For further details see "Alternative designs & Ordering information" below.

Technical characteristics

Hot junction

one

Ungrounded or Grounded

two

Vibration resistance GOST R 52931

group V3

Seismic resistance MSK-64

grade 9 for unit installation up to 70 m above zero mark

Climatic category GOST 15150

UHL2Ambient temperature:

-60..+120ºС for general purpose products

-60..+85 ºС for Ex version with analogous signal

-55..+85ºС for products with 4-20mА signal

Calibration

- MI 3090-2007 – for sensor fitting length 20 - 250 mm, without measuring transmitters;
- GOST 8.338-2001 – for sensor fitting length larger than 250 mm, without measuring transmitters;
- MP RT 2026-2013 – for sensors with installed measuring transmitters.

Reliability indicators

Reliability measures


Group of operating conditions

Probability of
failure-free operation

Specified lifetime

Mean
lifetime

Guarantee
conditions

II

0.95 for 16 000 hours

2 years

4 years

2 years

III

0.95 for 8 000 hours

1 year

2 years

1 year

IV

Not rated

Not rated

Not rated

Not rated

Error limits

Measurement accuracy of sensors with 4-20 mA DC signal and/or digital signal via HART protocol are given taking into account accuracies of thermocouple itself, transmitter and transmitter's cold junction.


Output signal

Symbol

Measurement accuracy

Output
signal

Symbol

Measurement accuracy

4-20mА

c0Т40

±0,4% ∙tn* or ±1,5°С

4-20mА+HART

c1N25

±0,25%∙ tn or ±0,9°С;

c1Т50

±0,5%∙ tn or ±2,0°С

c0N40

±0,4%∙ tn or ±1,2°С;

c2Т80

±0,8%∙ tn or ±2,5°С;

c1N50

±0,5%∙ tn or ±1,7°С;

 

 

c2N80

±0,8%∙ tn or ±2,5°С;

* - tn measuring transmitter adjustment range should be multiplied by specified value in %. Select higher value.

Temperature range

CT type

Modification

Thermowell diameter, mm

Thermowell material

Group of
operating
conditions

Application
temperature, ºС

Calibration
interval

Mean lifetime

CTL
CTK

01.11,
02.11

10

S10

II

-40…+600

2 years

4 years

III

-200…+800

1 year

2 years

CTK

10

T18

II

-40…+900

2 years

4 years

CTN

II

-40…+1000

2 years

4 years

CTN

01.14

22

Т45,
Т00

II

-200…+800

2 years

4 years

III

-200…+1100

1 year

2 years

CTK

II

-200…+600

2 years

4 years

III

-200…+900

1 year

2 years

IV

-200…+1150

Not rated

CTK

01.12, 01.13, 01.15

20

T310,
Т45

II

-200…+900

2 years

4 years

III

-200…+1100

1 year

2 years

IV

-200…+1150

Not rated

CTN

20

Т45

II

-200…+1000

2 years

4 years

IV

- 200…+ 1250

Not rated

Response time τ 0,63:


Hot junction

Sensor response time depending on diameter, s

modification
01.11

modification
01.14

01.15 modification

d=10/5; 20/5

d=10/7; 20/7

d = 22

d = 20

Insulated from sheath

5

7

8

40

Uninsulated from sheath

3

5

7

-

Execution options

CTK

 

 

01.14

0

21

c1

 

U

2

Т45

20

/

7

L

/

l

M33

1

 

2

3

 

4

5

 

6

7

 

8

9

 

10

 

11

 

12

 

13

 

14

 

15

 

NN

Name

Code

Description

1

Sensor type

CTK, CTL, CTN

Mineral insulated cable thermocouple with type according to IEC 60584 and ASTM E230

2

Explosion protection

Not filled

general purpose electrical equipment

Exi

0ExiaIICT6 X, intrinsically safe circuit

Exd

1ExdIICT6, explosion-proof enclosure

3

Modification

01.11

with protective tube and thinning

01.12

without mounting elements, fast-response

01.13

with welded fitting, fast-response

01.14

solid tapered tube with thinning

01.15

thermowell made of constant-diameter pipe

4

Cable gland

0

standard cable gland

Not permitted for 1ExdIICT6

А-Z

Special cable gland (see table 3 page 1-13)

5

Sensor terminal
head (see "Alternative designs" table, pages 1-10)

15; 16

aluminium head

IP66/IP68

1ExdIICT6 / 0ExiaIICT6 X

20; 22

aluminium head

IP65

general purpose

21; 23; 24; 25; 26; 28; 29

aluminium head

IP66

0ExiaIICT6 Х or general purpose

50

Stranded conductor, silicon / shield / silicon insulation - shield is insulated from sensor body and does not have a terminal

60

Stranded conductor, PTFE / shield / PTFE insulation - shield is insulated from sensor body and does not have a terminal

6

Tolerance class

c0;   c1;   c2

For further details see table 5 page 2-9

7

Output signal, transmitter accuracy symbol, see table 5, page 2-10

Not filled

analogous signal (mV) according to NSC

Т40

4-20 mА

for c0

Т50;  Т70

for c1

Т80;  Т100

for c2

H25

4-20 mА +HART

Individual sensor calibration (c1)

H40

for c0

H50

for c1

H80

for c2

8

Sensor hot junction design

G

grounded junction, general purpose

U

ungrounded junction

1ExdIICT6 / 0ExiaIICT6 X / general purpose

9

Number of wire couples

Not filled

1 wire couple

2

2 wire couples (2 junctions)

10

Protective sheath material

S10

steel 12Cr18Ni10T

Т310

AISI 310

Т45

alloy CrNi45U

11

Basic outer diameter

10; 20;  22

size (mm) on Customer's choice

12

Outer thinning diameter

5, 7

size (mm) on Customer's choice

Except for 01.15

13

Probe length

50÷2500

probe length L to the working end, mm

14

Extension neck length l

Not filled

if equal to 120 mm or there are no mounting elements

30÷500

specify dimension in mm, oif 120 mm doesn't fit

15

Fitting standard size

Specify thread size

C1/2, М27х2, М33х2

Except for 01.12

Examples of product designation


CTK 01.15-020 - c1 - U2 - Т45 - 20 – 800 – М33

Product type

CT

cable thermocouple

Type

K

chromel-alumel

Explosion protection

 

Modification

01.15

 

Cable gland

0

standard

Wring (terminal head code)

20

with latch, IP65

Tolerance class

c1

first class

Output signal

 

analogous

Junction type, number of pairs

U2

iwo, ungrounded

Cable sheath material

Т45

alloy CrNi45T

Working end diameter

20

mm

Probe length

800

mm

Extension neck length

120 mm

Fitting standard size

M33

М33х2