01.07
01.07
These sensors are designed for temperature measurement in liquid and gaseous non-corrosive media, and also corrosive media that do not damage protective cover material. Sensors are recommended to be used together with UNKJ thermowell. It is possible to use without thermowell if there is no aggressive chemical and/or mechanical influence.
It is recommended to insert 01.05 sensor in thermowell using UNKJ031 or UNKJ 038 fittings (see section "UNKJ units and components") to minimize thermal reaction between sensor and thermowell.
01.05 and 01.07 modifications are assembled. Replaceable sensitive elements are modifications CTxx 01.02-005...
21.05, 21.07 sensors are recommended if precision temperature measurement is required. Such precision is achieved due to periodic calibration or verification. Are analogous to 01.05 and 01.07 modifications correspondingly.
21.xx temperature sensor has an additional channel for control or reference thermocouple installation next to temperature-sensing element inside thermowell. Such construction allows to calibrate temperature-sensing element without thermocouple dismantling according to MI 3091--2007 (see pages 2-16). CETN 01 or CETN 02 are used as reference thermocouples (see section 8).
CTxx 21.XX thermocouple design is proved by patent for invention No. 2299408.
Sensors can be of explosion protection type 0ExiaIICT6 X or 1ExdIICT6 according to GOST 30852.10-2002. For further details see "Alternative designs ans Ordering information" below (except for 21.05, 21.07 modifications).
Terminal heads can be equipped with transmitters with 4-20 mА DC output signal and/or digital signal via HART, PROFIBUS-PA, FOUNDATION Fieldbus protocol. It is recommended to use heads of 16, 23, 28 modifications for easy wire connection to transmitters. Terminal head can be equipped with standard or special-purpose cable gland. For further details see "Alternative designs & Ordering information" below.
Hot junction |
one |
Ungrounded or Grounded |
||
two |
||||
Vibration resistance GOST R 52931 |
V3 group, for 01.10C modification -- F3 |
|||
Nominal (rated) |
6.3 MPa |
01.03, 01.26 modifications |
||
0.1 MPa |
01.04, 01.34 modifications |
|||
Seismic resistance MSK-64 |
grade 9 for unit installation up to 70 m above zero mark |
|||
Climatic category GOST 15150 |
UHL2Ambient temperature: |
-60..+120ºС for general purpose products |
||
-60..+85 ºС for Ex version with analogous signal |
||||
-55..+85ºС for produts with 4-20мА/HART signal |
||||
Calibration |
- MI 3090-2007 – for sensor fitting length 20 - 250 mm, without measuring transmitters; |
Group of operating conditions |
Probability of |
Specified lifetime |
Mean |
Guarantee |
I |
0.95 for 40 000 hours |
5 years |
10 years |
5 years |
II |
0.95 for 16 000 hours |
2 years |
4 years |
2 years |
III |
0.95 for 8 000 hours |
1 year |
2 years |
1 year |
IV |
Not rated |
Not rated |
Not rated |
Not rated |
Measurement accuracy of sensors with 4-20 mА DC signal and/or digital signal via HART protocol are given taking into account accuracies of thermocouple itself, transmitter and transmitter's cold junction compensation.
Output signal |
Symbol |
Measurement accuracy |
Output |
Symbol |
Measurement accuracy |
4-20mА |
c0Т40 |
±0,4% ∙tn* or ±1,5°С |
4-20mА+HART |
c1N25 |
±0,25%∙ tn or ±0,9°С; |
c1Т50 |
±0,5%∙ tn or ±2,0°С |
c0N40 |
±0,4%∙ tn or ±1,2°С; |
||
c2Т80 |
±0,8%∙ tn or ±2,5°С; |
c1N50 |
±0,5%∙ tn or ±1,7°С; |
||
|
|
c2N80 |
±0,8%∙ tn or ±2,5°С; |
* - tn sensor adjustment range should be multiplied by specified value in %. Select higher value.
CT type |
Thermowell diameter |
Thermowell material |
Group of operating conditions |
Application |
Calibration |
Mean lifetime |
CTN, CTK |
8; 10 |
S10 |
I |
-40…+600 |
5 years |
10 years |
II |
-200…+800 |
2 years |
4 years |
|||
CTK |
10 |
S13 |
I |
-40…+600 |
5 years |
10 years |
II |
-200…+900 |
2 years |
4 years |
|||
CTN |
10 |
S13 |
I |
-40…+800 |
5 years |
10 years |
II |
-200…+900 |
2 years |
4 years |
|||
CTK |
10 |
T18, Т45 |
I |
-40…+600 |
5 years |
10 years |
II |
-200…+900 |
2 years |
4 years |
|||
III |
-200…+1000 |
1 year |
2 years |
|||
CTN |
10 |
T18, Т45 |
I |
-40…+600 |
5 years |
10 years |
II |
-200…+1000 |
2 years |
4 years |
|||
CTN, CTK |
10 |
Т45 |
IV |
- 200…+ 1250 |
Not rated |
|
CTL |
8 (only S10); 10 |
S10, S13 |
I |
-40…+600 |
5 years |
10 years |
II |
-100…+800 |
2 years |
4 years |
|||
CTJ |
8 (only S10); 10 |
S10, S13 |
II |
-40…+760 |
2 years |
4 years |
Response time τ 0,63:
Hot junction |
Sensor response time depending on diameter, s |
|||
assembled modifications: |
fast-response modifications: |
|||
d = 8 |
d = 10 |
d = 8 |
d = 10 |
|
Insulated from sheath |
12 |
20 |
10 |
12 |
Uninsulated from sheath |
8 |
30 |
6 |
8 |
CTK |
|
Exi |
01.10 |
— |
А |
21 |
— |
c1 |
H50 |
— |
U |
|
— |
S10 |
— |
8 |
— |
L |
/ |
l |
|
|
1 |
|
2 |
3 |
|
4 |
5 |
|
6 |
7 |
|
8 |
9 |
|
10 |
|
11 |
|
12 |
|
13 |
|
14 |
NN |
Name |
Code |
Description |
||||
1 |
Sensor type |
CTK, CTL, CTN, CTJ, CTM |
Mineral insulated cable thermocouple with type according to IEC 60584 and ASTM E230 |
||||
2 |
Explosion protection |
Not filled |
general purpose electrical equipment |
||||
Exi |
0ExiaIICT6 X, intrinsically safe circuit |
||||||
Exd |
1ExdIICT6, explosion-proof enclosure |
||||||
3 |
Modification |
01.05, 21.05, 01.09 |
without mounting elements, with replaceable sensitive element |
||||
01.07, 21.07 |
with moveable fitting, with replaceable sensitive element |
||||||
01.26 |
fast-response with welded fitting |
||||||
01.10, 01.10С |
fast-response with moveable fitting |
||||||
4 |
Cable gland |
0 |
standard cable gland |
Not permitted for 1ExdIICT6 |
|||
А |
for unarmoured cable in metal hose RZCH-15 |
||||||
В |
for unarmoured cable in metal hose MRPI-15 |
||||||
C |
for unarmoured cable in metal hose DN18 |
||||||
D |
for unarmoured cable in metal hose DN20 |
||||||
E |
for unarmoured cable in metal hose DN12 |
||||||
F |
for pipe assembly, М20х1,5 internal thread |
||||||
G |
for pipe assembly, output external thread G1/2 |
||||||
H |
for unarmoured cable, 6.5 - 14 mm diameter |
||||||
I |
for unarmoured cable, 3.2 - 8.7 mm diameter |
||||||
J |
for cable with internal/external sheath diameter: 6,1-11,7/9,5-15,9, single-line wire armoured cable |
||||||
К |
for cable with internal/external sheath diameter: 3,1-8.7/6,1-11,5, all armour types |
||||||
L |
for cable with internal/external sheath diameter: 6,5-14/12,5-20,9, all armour types |
||||||
5 |
Sensor terminal |
10; 13 |
plastic head |
IP55 |
general purpose |
||
15; 16;17; 18; 19 |
aluminium head |
IP66/IP68 |
1ExdIICT6 / 0ExiaIICT6 X |
||||
20; 22 |
aluminium head |
IP65 |
general purpose |
||||
14; 21; 23; 24; 25; 26; 28; 29 |
aluminium head |
IP66 |
0ExiaIICT6Х or general purpose |
||||
27 |
stainless steel |
IP66 |
0ExiaIICT6Х or general purpose |
||||
6 |
Tolerance class |
c0; c1; c2 |
For further details see table 5 page 2-9 |
||||
7 |
Output signal, transmitter accuracy symbol, see table 5 at |
Not filled |
analogous signal according to NSC |
||||
Т40 |
For terminal heads >14 |
4-20 mА |
for c0 |
||||
Т50; Т70 |
for c1 |
||||||
Т80; Т100 |
for c2 |
||||||
N25 |
4-20 mА +HART |
Individual sensor calibration (c1) |
|||||
H40 |
for c0 |
||||||
H50 |
for c1 |
||||||
H80 |
for c2 |
||||||
8 |
Hot junction design |
G |
grounded |
general purpose |
|||
U |
ungrounded junction, |
1ExdIICT6 / 0ExiaIICT6 X / general purpose |
|||||
9 |
Number of wire couple |
Not filled |
1 wire couple |
||||
2 |
2 wire couples (2 junctions) |
||||||
10 |
Reinforcement material |
S10 |
steel 12Cr18Ni10T |
||||
S13 |
steel 10Cr17Ni3M2T |
||||||
T18 |
steel 10Cr23Ni18 |
||||||
Т45 |
alloy CrNi45U |
||||||
11 |
Outer diameter |
8; 10 |
size (mm) on Customer's choice |
||||
12 |
Probe length |
50÷3150 |
probe length L to the working end, mm |
||||
13 |
Extension neck length l |
Not filled |
if equal to 120 mm or there are no mounting elements |
||||
30÷500 |
specify dimension in mm, oif 120 mm doesn't fit |
||||||
14 |
Standard size |
Not filled |
if threaded fitting M20x1.5 or no fitting is used |
||||
Specify thread size |
in other cases |